

- #Transformer Winding Calculation Software software
- #Transformer Winding Calculation Software windows
Synchronous machines and synchronous condensers: Each machine can be controlled to hold constant voltage or constant power in a voltage-drop study.The total source load can be allocated to section loads using REA, kWh and kVA methods, as well as using line length. Distributed loads: modeled as ‘section loads’ on lines and cables.Spot loads and section loads modeled as a mixture of constant power, constant impedance and constant current components in voltage drop studies.2- and 3-way switches, circuit breakers, voltage regulators and boosters, switchable capacitors, grounding banks, and single-, 2-phase and 3-phase lines and cables.3-winding transformers without fictitious buses.2-winding transformers: Balanced 3-phase, as well as transformers that are made up of one, two or three single-phase banks with different kVA ratings and impedances.Has arc flash hazard calculator based on IEEE 1584-2011 and -2018 standards.Has a fault locator command that accept fault records from COMTRADE files, PDQ files and SEL event files with EVE or CEV extension.Has library of large number of commonly used conductors, pole constructions and underground cable circuits. Has built-in calculator for overhead-lines and cable impedances.Has the ability to calculate feeder reliability.Has built-in harmonic analysis engine for frequency scan and harmonic load-flow solution.Has advanced analysis tools: stepped-event analysis, voltage sag analysis, arc-flash calculation and more.Short-circuit and locked-rotor studies can use a voltage-drop solution as initial condition.Simulates voltage drop with a true 3-phase load flow algorithm.Simulates distribution transformer faults and reports on fault current on the low side.

Simulates lock-rotor condition for single- and 3-phase induction machines, with a variety of starting methods.Simulate short circuits: bus faults, close-in faults, line-end faults and intermediate faults.Each feeder can be fed by any number of substation buses. Models the distribution network in the phase domain (and not in the sequence domain) for short-circuit, locked-rotor and voltage-drop (load-flow) studies.
#Transformer Winding Calculation Software windows
#Transformer Winding Calculation Software software
ASPEN DistriView™ is an integrated suite of voltage drop, short circuit, relay coordination, and harmonics and reliability calculation software for utility distribution systems.
